-25%
, , ,

Schneider C100H420FM | Circuit breaker, ComPacT NS1000H, 70kA at 415VAC, 4P, fixed, manually operated, MicroLogic 2.0 control unit, 1000A

Availability:

Out of stock


  • Schneider C100H420FM | Circuit breaker, ComPacT NS1000H, 70kA at 415VAC, 4P, fixed, manually operated, MicroLogic 2.0 control unit, 1000A

ComPacT NS is a range of circuit breakers for built-in power & energy metering

The solution covers ratings from 630 A to 3200 A
MicroLogic electronic control unit provides electrical measurement and analysis functions
ComPacT NS offers an optimized range of auxiliaries and accessories, field installable
Flexible installation, in any position, in a switchboard or wall-mounted

174,313.54 EGP 233,445.21 EGP

Out of stock

Schneider C100H420FM | Circuit breaker, ComPacT NS1000H, 70kA at 415VAC, 4P, fixed, manually operated, MicroLogic 2.0 control unit, 1000A

 

 Technical Specifications

  • Product Type: Molded Case Circuit Breaker (MCCB)

  • Model Code: C100H420FM

  • Series: ComPacT NS1000H

  • Rated Current (In): 1000 Amps

  • Poles: 4 poles (3 phases + neutral)

  • Rated Operational Voltage (Ue): Up to 690 VAC

  • Rated Insulation Voltage (Ui): 800 V

  • Rated Impulse Withstand Voltage (Uimp): 8 kV

  • Breaking Capacity (Icu): 70 kA at 415 VAC (according to IEC 60947-2)

  • Trip Unit: MicroLogic 2.0 – electronic, with adjustable protection settings and monitoring capability

  • Mounting: Fixed

  • Operation Mode: Manual

  • Frequency: 50/60 Hz

  • Protection Class: IP20 (when mounted inside an enclosure)

  • Standards Compliance: IEC 60947-2

  • Schneider C100H420FM | Circuit breaker, ComPacT NS1000H, 70kA at 415VAC, 4P, fixed, manually operated, MicroLogic 2.0 control unit, 1000A

 Key Features

  • High Fault Protection: With a breaking capacity of 70kA at 415VAC, it offers superior protection during short-circuit conditions.

  • Smart MicroLogic 2.0 Trip Unit: Enables fine-tuning of protection thresholds and real-time monitoring, enhancing safety and energy efficiency.

  • Four-Pole Configuration: Provides full-phase and neutral protection, ideal for balanced and unbalanced 3-phase systems.

  • High Current Handling (1000A): Suitable for heavy-duty applications that demand high power throughput.

  • Reliable Manual Operation: Simple, direct switching suitable for industrial environments and emergency interventions.

  • Rugged and Compact Design: Built for tough industrial conditions, while maintaining a compact footprint for easy panel integration.

Typical Applications

The Schneider C100H420FM is engineered for medium and large-scale power distribution systems across many sectors:

  • Main Distribution Boards:
    Used as a main breaker in large industrial and commercial electrical panels.

  • Power Infrastructure & Utilities:
    Ideal for protecting feeders from transformers, backup generators, and switchgear systems.

  • Critical Facilities:
    Hospitals, airports, and data centers where reliable power protection is non-negotiable.

  • Industrial Plants:
    For protecting heavy machinery, compressors, and large motors from electrical faults.

  • Commercial Complexes & High-Rise Buildings:
    Effective in large-scale electrical networks with multiple sub-circuits and high load demand.

brands

Schneider Electric

Main
Range ComPacT
Product name ComPacT NS new generation
Range of product ComPacT NS630b…1600 new generation
Product or component type Circuit breaker
Device application Distribution
Number of poles 4P
Protected poles description 4D
Neutral position Left
[In] rated current 1000 A at 50 °C
[Ue] rated operational voltage 690 V AC 50/60 Hz
Network type AC
Network frequency 50/60 Hz
Suitability for isolation Yes conforming to EN/IEC 60947-2
Utilisation category Category B
Breaking capacity 85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
70 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 500/525 V AC 50/60 Hz conforming to IEC 60947-2
42 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity code H 70 kA 415 V AC
Trip unit name MicroLogic 2.0
Trip unit technology Electronic
Trip unit protection functions LI
Control type Manually operated
Mounting mode Fixed
Complementary
[Ui] rated insulation voltage 800 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947-2
[Ics] rated service breaking capacity 52 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
52 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
48 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
37 kA at 500/525 V AC 50/60 Hz conforming to IEC 60947-2
31 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
[Icw] rated short-time withstand current 19.2 kA 1 s conforming to IEC 60947-2
Mechanical durability 10000 cycles
Electrical durability 2000 cycles at 690 V In
4000 cycles at 690 V In/2
5000 cycles at 440 V In
6000 cycles at 440 V In/2
Power losses 22 W
Mounting support Backplate
Upside connection Front
Downside connection Front
Connection pitch 70 mm
Protection type L : for overload protection (long time)
I : for instantaneous short-circuit protection
Trip unit rating 1000 A at 50 °C
Long-time pick-up adjustment type Ir (thermal protection) Adjustable 9 settings
[Ir] long-time protection pick-up adjustment range 0.4…1 x In
Long-time protection delay adjustment type tr Adjustable 9 settings
[tr] long-time delay adjustment range 12.5…600 s at 1.5 x Ir
0.5…24 s at 6 x Ir
0.7…16.6 s at 7.2 x Ir
Thermal memory 20 mn
Instantaneous protection pick-up adjustment type Ii Adjustable
[Ii] instantaneous protection pick-up adjustment range 1.5…10 x Ir
Earth-leakage protection Without
Neutral protection setting No protection (3D)
0.5 x Ir (3D + N/2)
1 x Ir (4D)
Zone selective interlocking ZSI Without
Auxiliary contact composition 1 NO/NC
Local signalling 4 LEDs (red) for fault indication
1 LED (yellow) for overload
Width (W) 280 mm
Height (H) 327 mm
Depth (D) 147 mm
Net weight 18 kg
Environment
Standards EN/IEC 60947-2
Product certifications IECEE CB Scheme
Overvoltage category III
Electrical shock protection class Class II on front face
Pollution degree 3 conforming to IEC 60947
IP degree of protection IP40 conforming to IEC 60529
IK degree of protection IK07 conforming to EN 50102
Ambient air temperature for operation -25…70 °C
Ambient air temperature for storage -50…85 °C
Relative humidity 0…95 %
Operating altitude 0…2000 m without derating
2000 m…5000 m with derating
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 30.000 cm
Package 1 Width 40.000 cm
Package 1 Length 60.000 cm
Package 1 Weight 16.460 kg

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider C100H420FM | Circuit breaker, ComPacT NS1000H, 70kA at 415VAC, 4P, fixed, manually operated, MicroLogic 2.0 control unit, 1000A”

There are no reviews yet.