Schneider C080H420FM | Circuit breaker, ComPacT NS800H, 70kA at 415VAC, 4P, fixed, manually operated, MicroLogic 2.0 control unit, 800A
Description
Schneider C080H420FM – ComPacT NS800H – 800A – 4P – MicroLogic 2.0
The Schneider C080H420FM is a high-performance molded case circuit breaker from the ComPacT NS800H range, specifically designed to protect low-voltage electrical systems in industrial and commercial applications.
With a rated current of 800 amps and a breaking capacity of 70kA at 415V AC, this circuit breaker is capable of safely handling high fault levels, ensuring reliable protection for critical installations. The 4-pole design offers full protection for three-phase systems including the neutral conductor, enhancing system safety and balance.
This model is built for fixed installation and operates manually, making it suitable for main distribution boards where durability, ease of use, and accessibility are key.
At the core of its protection capabilities is the MicroLogic 2.0 trip unit, which provides accurate, adjustable electronic protection. It supports long-time, short-time, and instantaneous trip settings, allowing flexible adaptation to system requirements and minimizing downtime due to false tripping.
Fully compliant with IEC 60947-2, the C080H420FM offers exceptional performance, mechanical strength, and long-term reliability, making it an excellent choice for demanding electrical environments where high fault protection and system continuity are critical.
Detailed Feature Description:
1. Rated Current – 800A:
This MCCB is built to carry and protect circuits with up to 800 amps of continuous current. It ensures that the load is disconnected if the current exceeds this limit over time (overload condition).
2. 4 Poles (4P):
The breaker protects all three phases plus the neutral conductor, which is essential in 3-phase + neutral systems. Neutral protection is useful when the load is unbalanced or has significant harmonic currents.
3. Breaking Capacity – 70kA:
With a breaking capacity of 70,000 amps, this breaker is suitable for installations where high fault currents may occur, such as main incoming panels, transformer connections, or large industrial systems.
4. Fixed Mounting:
This model is permanently mounted into a switchboard or panel. It’s not designed to be removed or withdrawn during operation, making it compact, reliable, and cost-effective, although maintenance requires power disconnection.
5. Manual Operation:
The breaker is operated using a manual handle, allowing the user to turn it ON or OFF locally. There’s no motorized or remote switching function in this model.
6. Trip Unit – MicroLogic 2.0:
MicroLogic 2.0 is a basic electronic trip unit that offers precise protection functions:
-
Long-time delay: For gradual overload conditions
-
Short-time delay: For short-circuit currents just above the normal load
-
Instantaneous: For very high short-circuit faults
Note: MicroLogic 2.0 is focused purely on protection and does not include energy metering, communication, or remote monitoring.
Typical Applications:
-
Industrial main distribution boards
-
Generator or transformer output protection
-
UPS systems and backup power circuits
-
Facilities requiring 3-phase + neutral protection
-
High-power machinery and critical load centers
Key Advantages:
-
High current handling (800A)
-
Strong short-circuit interruption (70kA)
-
Full 4-pole protection (L1, L2, L3 + Neutral)
-
Accurate and fast electronic tripping
-
Durable, space-saving, and trusted for long-term reliability







There are no reviews yet.